{"product_id":"dantherm-ac-r6000","title":"Dantherm air cooling system Dantherm Group AC-R6000","description":"\u003ch2\u003eDantherm air cooling system Dantherm Group AC-R6000\u003c\/h2\u003e\n\u003ch3\u003eWhat it is\u003c\/h3\u003e\n\u003cp\u003eDantherm air cooling system Dantherm Group AC-R6000. Key specifications: operating temperature range, cooling +25 – +51 ºC, air flow rate (m³\/h) 1.400, cooling capacity, 51\/41 °C, 30% RH (kW) 6,1.\u003c\/p\u003e\n\u003cp\u003eAn industrial cooler is a portable air conditioner, evaporative cooler or fan that lowers the temperature or moves air in warehouses, construction sites and plant rooms.\u003c\/p\u003e\n\u003ch3\u003eWhat it is for\u003c\/h3\u003e\n\u003cp\u003eUsed for air conditioning industrial premises, for dehumidifying indoor spaces and for ventilating workplaces.\u003c\/p\u003e\n\u003ch3\u003eHow to use it\u003c\/h3\u003e\n\u003cp\u003ePlace portable air conditioners near an opening, with the hot air hose venting outside and the condensate drain connected or emptied; fill evaporative coolers with clean water. Set fans down securely, with the guard intact, directing the airflow towards workstations. Clean filters and grilles regularly and connect the units to protected sockets.\u003c\/p\u003e\n\u003ch3\u003eWhere it is used\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003eEvents and exhibition fit-out\u003c\/li\u003e\u003cli\u003eMechanical engineering industry\u003c\/li\u003e\u003cli\u003eLogistics and warehousing\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eOperating temperature range, cooling:\u003c\/strong\u003e +25 – +51 ºC\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eAir flow rate (m³\/h):\u003c\/strong\u003e 1.400\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eCooling capacity, 51\/41 °C, 30% RH (kW):\u003c\/strong\u003e 6,1\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eCooling capacity, 35\/27 °C, 38% RH (kW):\u003c\/strong\u003e 3,7\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eMax current, cooling\/heating operation (A):\u003c\/strong\u003e 14,9\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eLocked rotor current, LRA (A):\u003c\/strong\u003e 35,5\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eGWP global warming potential:\u003c\/strong\u003e 148\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eIngress protection for electrical parts:\u003c\/strong\u003e IPX5\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eSound emission level at 1 m (dB(A)):\u003c\/strong\u003e 60\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eFresh air intake:\u003c\/strong\u003e 0 to 200 m³\/h\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eFresh air intake\/recirculation filter:\u003c\/strong\u003e Coarse type\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHandling:\u003c\/strong\u003e On wheels or by forklift\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003ePower cable with plug:\u003c\/strong\u003e 10m with CEE 3P 6H-IP54,230V,16A\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eFlexible hose connection:\u003c\/strong\u003e Ø315 Ømm\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eDesigned for industrial maintenance technicians and HVAC technicians.\u003c\/p\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range, cooling\u003c\/td\u003e\n\u003ctd\u003eºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range, heating\u003c\/td\u003e\n\u003ctd\u003eºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir flow\u003c\/td\u003e\n\u003ctd\u003em³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling capacity @ 51\/41°C 30% RH\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling capacity @ 35\/27°C 38% RH\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating capacity\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eV\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. operating current, cooling\/heating\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eType\/kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system pressure\u003c\/td\u003e\n\u003ctd\u003ebar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGWP (global warming potential)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower cable with plug\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003ekg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRelated products\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/trotec-pac-w-2650-sh\"\u003eTrotec PAC-W 2650 SH air cooling system Dantherm Group\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/dantherm-ac-r18000\"\u003eDantherm air cooling system Dantherm Group AC-R18000\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/aerial-ad-40\"\u003eDehumidifier Aerial AD 40 Dantherm Group\u003c\/a\u003e \u0026mdash; from the category \u003ca href=\"\/en\/collections\/deumidificatori-e-pompe-di-calore\"\u003eDehumidifiers and Heat Pumps\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/master-prolunga-16a-5-m-per-riscaldatori-e-deumidificatori-dantherm-group\"\u003eExtension lead – 16A \/ 5 m for Master heaters and dehumidifiers, Dantherm Group\u003c\/a\u003e \u0026mdash; from the category \u003ca href=\"\/en\/collections\/spine-e-prese-uso-industriale-e-da-cantiere-heavy-duty-ip44-iec-60309-certificate-stagne-alta-protezione-ip67\"\u003eSite Electrical Equipment: Plugs, Sockets, Cables and Extension Leads\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/heylo-dcs-pf-1000\"\u003eAir purifier Heylo DCS-PF 1000\u003c\/a\u003e \u0026mdash; from the category \u003ca href=\"\/en\/collections\/sistemi-di-ventilazione-e-griglie-areazione\"\u003eVentilation Systems, Air Grilles and Vents\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003eBrowse the whole category: \u003ca href=\"\/en\/collections\/raffreddatori-ambienti-industriali\"\u003eIndustrial Space Coolers\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eBefore you order\u003c\/h3\u003e\n\u003cp\u003eIn your request, please state the rated load or flow rate and the quantities required, so we can give you the right quotation first time.\u003c\/p\u003e\n\u003cp\u003eFor prices and availability, \u003cstrong\u003erequest a quote from AMES Srl\u003c\/strong\u003e: we will reply with our quotation, delivery times and, where needed, an equivalent technical alternative.\u003c\/p\u003e","brand":"Dantherm Group","offers":[{"title":"Standard","offer_id":57763010838860,"sku":"dantherm-ac-r6000","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/9864\/0716\/files\/AC-R-6000_front.jpg?v=1781107695","url":"https:\/\/www.amesworldwide.com\/products\/dantherm-ac-r6000","provider":"A.M.E.S. srl","version":"1.0","type":"link"}