{"product_id":"dantherm-hcc-360p2","title":"Ventilation system Dantherm Hcc 360P2","description":"\u003ch2\u003eVentilation system Dantherm Hcc 360P2\u003c\/h2\u003e\n\u003ch3\u003eWhat it is\u003c\/h3\u003e\n\u003cp\u003eVentilation system Dantherm Hcc 360P2. Key specifications: max capacity 360 V100Pa| m³\/h, max rated flow at 100 Pa 220 Vmax.rated \/ m³\/h, recommended field of use 50 - 220 V | m³\/h.\u003c\/p\u003e\n\u003cp\u003eThese are air treatment units and components: fans, air purifiers, sanitising systems, heat pumps, ducting, grilles and ventilation fittings.\u003c\/p\u003e\n\u003ch3\u003eWhat it is for\u003c\/h3\u003e\n\u003cp\u003eUsed in air conditioning and air handling systems and for ventilating workplaces.\u003c\/p\u003e\n\u003ch3\u003eHow to use it\u003c\/h3\u003e\n\u003cp\u003eChoose the unit according to the room volume and place it on a stable base, with unobstructed air inlets and ducts as short and straight as possible. Use ozone generators only in rooms with no people or animals present, ventilating before re-entering. Clean or replace filters and grilles periodically.\u003c\/p\u003e\n\u003ch3\u003eWhere it is used\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003eResidential construction\u003c\/li\u003e\u003cli\u003eBuilding services\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eMax capacity:\u003c\/strong\u003e 360 V100Pa| m³\/h\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eMax rated flow at 100 Pa:\u003c\/strong\u003e 220 Vmax.rated \/ m³\/h\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eRecommended field of use:\u003c\/strong\u003e 50 - 220 V | m³\/h\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eEN 131417 reference flow 50pa:\u003c\/strong\u003e 154 VREF | m³\/h\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eThermal efficiency EN 13141 7 at reference flow:\u003c\/strong\u003e 88 ηEN | %\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eInternal and external leakage to EN:\u003c\/strong\u003e \u0026lt;2% (Class A1) class\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eFilters according to EN 779:\u003c\/strong\u003e G4 (optional on supply: F7)\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eMaximum humidity in extract air at 25°C:\u003c\/strong\u003e 55 RH %\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eOutdoor temperature range without preheating:\u003c\/strong\u003e -12 to +45 tODA | °C\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eOutdoor temperature range with preheating ins:\u003c\/strong\u003e -15 to +45 tODA | °C\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eSpigot\/duct connections:\u003c\/strong\u003e 125 – female Ømm\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eWeight (kg):\u003c\/strong\u003e 34\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHeat conductivity, polystyrene insulation:\u003c\/strong\u003e 0.031 λ | W\/mK\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHeat transfer coefficient, polystyrene insulat:\u003c\/strong\u003e \u0026lt;1 U | W\/m2K\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eDesigned for HVAC technicians and heating and plumbing engineers.\u003c\/p\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation surrounding temperature range\u003c\/td\u003e\n\u003ctd\u003etSURR | °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum humidity in extract air at 25°C\u003c\/td\u003e\n\u003ctd\u003eRH %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor temperature range without preheating installed\u003c\/td\u003e\n\u003ctd\u003etODA | °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor temperature range with preheating installed\u003c\/td\u003e\n\u003ctd\u003etODA | °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (without wall bracket)\u003c\/td\u003e\n\u003ctd\u003ew x d x h | mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRelated products\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/dantherm-hch-5\"\u003eVentilation system Dantherm Hch 5\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/dantherm-hcc-360e1\"\u003eVentilation system Dantherm Hcc 360E1\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/aerial-ad-110\"\u003eDehumidifier Aerial AD 110 Dantherm Group\u003c\/a\u003e \u0026mdash; from the category \u003ca href=\"\/en\/collections\/deumidificatori-e-pompe-di-calore\"\u003eDehumidifiers and Heat Pumps\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/master-anello-adattatore-o508-mm-per-riscaldatori-daria-elettrici-rs-40-dantherm-group\"\u003eAdapter Ring - Ø508mm for RS 40 Electric Air Heaters, Master, Dantherm Group\u003c\/a\u003e \u0026mdash; from the category \u003ca href=\"\/en\/collections\/generatori-daria-calda-elettrici-e-a-gas\"\u003eElectric and Gas Hot Air Heaters\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/master-prolunga-16a-5-m-per-riscaldatori-e-deumidificatori-dantherm-group\"\u003eExtension lead – 16A \/ 5 m for Master heaters and dehumidifiers, Dantherm Group\u003c\/a\u003e \u0026mdash; from the category \u003ca href=\"\/en\/collections\/spine-e-prese-uso-industriale-e-da-cantiere-heavy-duty-ip44-iec-60309-certificate-stagne-alta-protezione-ip67\"\u003eSite Electrical Equipment: Plugs, Sockets, Cables and Extension Leads\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003eBrowse the whole category: \u003ca href=\"\/en\/collections\/sistemi-di-ventilazione-e-griglie-areazione\"\u003eVentilation Systems, Air Grilles and Vents\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eBefore you order\u003c\/h3\u003e\n\u003cp\u003eIn your request, please state the rated load or flow rate and the quantities required, so we can give you the right quotation first time.\u003c\/p\u003e\n\u003cp\u003eFor prices and availability, \u003cstrong\u003erequest a quote from AMES Srl\u003c\/strong\u003e: we will reply with our quotation, delivery times and, where needed, an equivalent technical alternative.\u003c\/p\u003e","brand":"Dantherm Group","offers":[{"title":"Standard","offer_id":57763014312268,"sku":"dantherm-hcc-360p2","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/9864\/0716\/files\/Dantherm-HCC-2_447e80e4-e1fb-4957-a5b2-ea31d66ac51d.jpg?v=1781107735","url":"https:\/\/www.amesworldwide.com\/products\/dantherm-hcc-360p2","provider":"A.M.E.S. srl","version":"1.0","type":"link"}